Displaying 51 - 75 of 106

Dependence of transition width on current and critical current in transition-edge sensors

December 7, 2017
Author(s)
Kelsey M. Morgan, Christine G. Pappas, Douglas A. Bennett, Johnathon D. Gard, James P. Hays-Wehle, Gene C. Hilton, Carl D. Reintsema, Daniel R. Schmidt, Joel N. Ullom, Daniel S. Swetz
If transition-edge sensor (TES) X-ray detectors are to be useful in photon-rich environments,they must maintain high resolving power when pulse durations are engineered to be short, which is usually accomplished by increasing the thermal conductance (G)to

Microwave SQUID Multiplexer for Cosmic Microwave Background Imagers

October 11, 2017
Author(s)
Bradley J. Dober, Daniel T. Becker, Douglas A. Bennett, Sean A. Bryan, Shannon M. Duff, Johnathon D. Gard, James P. Hays-Wehle, Johannes Hubmayr, John A. Mates, Carl D. Reintsema, Leila R. Vale
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we

Simultaneous readout of 128 X-ray and Gamma-ray Transition-edge Microcalorimeters using Microwave SQUID Multiplexing

August 8, 2017
Author(s)
John Mates, Dan Becker, Douglas Bennett, Johnathon Gard, James P. Hays-Wehle, Joseph Fowler, Gene C. Hilton, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Leila R. Vale, Joel Ullom
The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the array into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES)

A Reassessment of Absolute Energies of X-ray L Lines of Lanthanide Metals

June 28, 2017
Author(s)
Bradley Alpert, W.Bertrand (Randy) Doriese, Gene C. Hilton, Lawrence T. Hudson, Young I. Joe, Kelsey Morgan, Carl D. Reintsema, Dan Schmidt, Daniel Swetz, Csilla Szabo-Foster, Joel Ullom, Joseph Fowler, Galen O'Neil, Douglas Bennett
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

May 16, 2017
Author(s)
William B. Doriese, Peter Abbamonte, Douglas A. Bennett, Edward V. Denison, Yizhi Fang, Daniel A. Fischer, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Cherno Jaye, Jessica L. McChesney, Luis Miaja Avila, Kelsey M. Morgan, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Fanny Rodolakis, Daniel R. Schmidt, Hideyuki Tatsuno, Jens Uhlig, Leila R. Vale, Joel N. Ullom, Daniel S. Swetz
We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more

First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy

September 30, 2016
Author(s)
Douglas Bennett, W.Bertrand (Randy) Doriese, Joseph Fowler, Johnathon Gard, James P. Hays-Wehle, Gene C. Hilton, Carl D. Reintsema, Daniel Swetz, Joel Ullom
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES)microcalorimeters at the πM1 beam line of the Paul Scherrer Institute. The pionic-carbon 4 → 3

Code-division-multiplexed readout of large arrays of TES microcalorimeters

September 15, 2016
Author(s)
Kelsey M. Morgan, Bradley K. Alpert, Douglas A. Bennett, William B. Doriese, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kent D. Irwin, Young Il Joe, Galen C. O'Neil, Carl D. Reintsema, Edward V. Denison, Daniel R. Schmidt, Joel N. Ullom, Daniel S. Swetz
Code-division multiplexing (CDM) offers a path to reading out large arrays of transition edge sensor (TES) X-ray micro-calorimeters with excellent energy and timing resolution. We demonstrate the readout of X-ray TESs with a 32-channel flux-summed code

Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

January 19, 2016
Author(s)
Hideyuki Tatsuno, William B. Doriese, Douglas A. Bennett, Catalina Curceanu, Joseph W. Fowler, Johnathon D. Gard, Fredrick P. Gustafsson, Tadashi Hashimoto, Ryugo S. Hayano, James P. Hays-Wehle, Gene C. Hilton, Mihail Iliescu, Shigeru Ishimoto, Kenta Itahashi, Masashiko Iwasaki, Keisuke Kuwabara, Yue Ma, Johann Marton, Hirofumi Noda, Galen C. O'Neil, Shinji Okada, Haruhiko Outa, Carl D. Reintsema, Masaharu Sato, Daniel R. Schmidt, Hexi Shi, Ken Suzuki, Takatoshi Suzuki, Jens Uhlig, Joel N. Ullom, Eberhard Widmann, Shinya Yamada, Johann Zmeskal, Daniel S. Swetz
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV

Algorithms for Identification of Nearly-Coincident Events in Calorimetric Sensors

December 29, 2015
Author(s)
Bradley K. Alpert, Elena Ferri, Douglas A. Bennett, Marco Faverzani, Joseph W. Fowler, Andrea Giachero, James P. Hays-Wehle, Angelo Nucciotti, Daniel S. Swetz, Joel N. Ullom
For experiments with high arrival rates, reliable identification of nearly-coincident events can be crucial. For calorimetric measurements to directly measure the neutrino mass such as HOLMES, unidentified pulse pile-ups are expected to comprise a leading

Developments in time-division multiplexing of X-ray transition-edge sensors.

December 8, 2015
Author(s)
William B. Doriese, Kelsey M. Morgan, Douglas A. Bennett, Edward V. Denison, Colin P. Fitzgerald, Joseph W. Fowler, Johnathon D. Gard, James P. Hays-Wehle, Gene C. Hilton, Kent D. Irwin, Young Il Joe, John A. Mates, Galen C. O'Neil, Carl D. Reintsema, Nigel O. Robbins, Daniel R. Schmidt, Daniel S. Swetz, Hideyuki Tatsuno, Joel N. Ullom, Leila R. Vale
Time-division multiplexing (TDM) is a mature scheme for the readout of transition-edge sensors. Variants of TDM, which is based on superconducting-quantum-interference-device (SQUID) current amplifiers, have to date been field-deployed in several

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

May 1, 2015
Author(s)
W.Bertrand (Randy) Doriese, Joseph Fowler, Daniel Swetz, Cherno Jaye, Daniel A. Fischer, Carl D. Reintsema, Douglas Bennett, Leila R. Vale, Gene C. Hilton, Dan Schmidt, Joel Ullom, Jens Uhlig, Ujjwal Mandal, Galen O'Neil, Luis Miaja Avila, Young I. Joe, wilfrid fullagar, Fredrick P. Gustafsson, Dharma Kurunthu, Villy Sundstrom
X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low

Measurement of the 240Pu/239Pu Mass Ratio Using a Transition-Edge-Sensor Microcalorimeter for Total Decay Energy Spectroscopy

February 27, 2015
Author(s)
Daniel R. Schmidt, Douglas A. Bennett, James P. Hays-Wehle, Daniel S. Swetz, Joel N. Ullom, Andrew Hoover, Mark Croce, Michael W. Rabin, Evelyn Bond, Terry Holesinger, Gerd Kunde, Laura Wolfsbereg
We have developed a new category of sensor for measurement of the 240Pu/239Pu mass ratio from aqueous solution samples with advantages over existing methods. Aqueous solution plutonium samples were evaporated and encapsulated inside of a gold foil absorber